Opis
Neposredni zaganjalnik z magnetnim sprožilcem do 15 kWKombinacija motornega zaščitnega stikala TeSys GV2 s kontaktorjem TeSys D zagotavlja največjo zanesljivost, kompaktne izvedbe in najlažjo izbiro.
Besedilo je strojno prevedeno.
Varnost izdelkov (GPSR)
Proizvajalčeva koda: LE1D09P7
EAN koda: 3389110541243
Registrirana blagovna znamka: Schneider Electric
Ime proizvajalca: Schneider Electric GmbH
Naslov proizvajalca: Gothaer Str. 29
Poštna številka proizvajalca: 40880
Kraj proizvajalca: Ratingen
Država proizvajalca: Germany
Telefon proizvajalca: +4921173743000
Elektronski kontakt proizvajalca: https://www.se.com/
Kontakt odgovorne osebe za varnost: [email protected]
Država odgovorne osebe za varnost: Nemčija
Dokumenti
Tehnični podatki
| Vrsta izdelka |
neposredni zaganjalnik |
|---|---|
| Moč motorja pri 400 V |
2.2 kW |
| Proizv. št. delov |
LE1D09P7 |
| Vrsta |
LE1D09P7 |
| Mere |
(Š x V x G) 88 x 166 x 128 mm |
| Širina |
88 mm |
| Višina |
166 mm |
| Globina |
128 mm |
| Width |
88 |
| Height |
166 mm |
| Depth |
128.5 mm |
| With transformer |
FALSE |
| Rated operation power at AC-3, 400 V |
4 kW |
| Number of command positions |
2 |
| Number of auxiliary contacts as normally open contact |
0 |
| Number of auxiliary contacts as normally closed contact |
0 |
| Suitable for emergency stop |
FALSE |
| Rated operation current Ie |
9 A |
| Number of indicator lights |
0 |
| Supporting protocol for LON |
FALSE |
| Supporting protocol for TCP/IP |
FALSE |
| Supporting protocol for ASI |
FALSE |
| Supporting protocol for PROFIBUS |
FALSE |
| Supporting protocol for CAN |
FALSE |
| Supporting protocol for INTERBUS |
FALSE |
| Supporting protocol for Modbus |
FALSE |
| Supporting protocol for Data-Highway |
FALSE |
| Supporting protocol for DeviceNet |
FALSE |
| Supporting protocol for SUCONET |
FALSE |
| Supporting protocol for other bus systems |
FALSE |
| External reset possible |
TRUE |
| Suitable for rail mounting |
FALSE |
| Degree of protection (IP) |
IP65 |
| Supporting protocol for SERCOS |
FALSE |
| Supporting protocol for INTERBUS-Safety |
FALSE |
| With short-circuit release |
FALSE |
| With fuse |
FALSE |
| Type of electrical connection of main circuit |
Screw connection |
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection |
| Supporting protocol for AS-Interface Safety at Work |
FALSE |
| Supporting protocol for DeviceNet Safety |
FALSE |
| Supporting protocol for EtherNet/IP |
FALSE |
| Supporting protocol for Foundation Fieldbus |
FALSE |
| Supporting protocol for PROFINET CBA |
FALSE |
| Supporting protocol for PROFINET IO |
FALSE |
| Supporting protocol for PROFIsafe |
FALSE |
| Supporting protocol for SafetyBUS p |
FALSE |
| Voltage type for actuating |
AC |
| Type of motor starter |
Direct online starter (DOL) |
| Rated operation power at AC-3, 230 V, 3-phase |
2.2 kW |
| Rated power, 460 V, 60 Hz, 3-phase |
4 kW |
| Rated power, 575 V, 60 Hz, 3-phase |
5.5 |
| Rated operation current at AC-3, 400 V |
9 A |
| Ambient temperature, upper operating limit |
40 °C |
| UKCA |
da |

0 od 5