Varnost izdelkov (GPSR)
Proizvajalčeva koda: 3LD20842GP21
EAN koda: 4001869573991
Registrirana blagovna znamka: Siemens
Ime proizvajalca: Siemens AG
Naslov proizvajalca: Siemenspromenade 2
Poštna številka proizvajalca: 91058
Kraj proizvajalca: Erlangen
Država proizvajalca: Germany
Telefon proizvajalca: +498938035491
Elektronski kontakt proizvajalca: https://www.siemens.com/
Kontakt odgovorne osebe za varnost: [email protected]
Država odgovorne osebe za varnost: Nemčija
Dokumenti
Tehnični podatki 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Navodila za uporabo in varnost 2870056 Siemens 3LD20842GP21
Tehnični podatki
| Rated operation power at AC-3, 400 V |
6 kW |
|---|---|
| Number of auxiliary contacts as normally open contact |
1 |
| Number of auxiliary contacts as normally closed contact |
1 |
| Rated permanent current Iu |
16 A |
| Number of poles |
3 |
| Degree of protection (IP), front side |
IP65 |
| Number of auxiliary contacts as change-over contact |
0 |
| Number of switches |
1 |
| Interlockable |
TRUE |
| Motor drive integrated |
FALSE |
| Type of electrical connection of main circuit |
Frame clamp |
| Version as emergency stop installation |
FALSE |
| Type of control element |
Wing knob |
| Version as main switch |
TRUE |
| Version as safety switch |
FALSE |
| Version as maintenance-/service switch |
TRUE |
| Rated operation power at AC-23, 400 V |
7.5 kW |
| Rated short-time withstand current lcw |
0.34 kA |
| Colour control element |
Black |
| Suitable for floor mounting |
FALSE |
| Suitable for front mounting 4-hole |
FALSE |
| Suitable for front mounting centre |
TRUE |
| Suitable for distribution board installation |
FALSE |
| Suitable for intermediate mounting |
FALSE |
| Max. rated operation voltage Ue AC |
690 V |
| Motor drive optional |
FALSE |
| Voltage release optional |
FALSE |
| Device construction |
Built-in device fixed built-in technique |
| Rated permanent current at AC-21, 400 V |
16 A |
| Version as reversing switch |
FALSE |
| Rated permanent current at AC-23, 400 V |
16 |
| Degree of protection (NEMA) |
Other |
| UKCA |
da |

0 od 5